- Independent testing
Envirolyte systems and generated solutions (anolyte and catolyte) have been put through extensive series of independent tests and on-site trials including hospitals, breweries, water systems and agricultural environments. - Safer world
Being environmentally friendly, completely safe, non-toxic and non-irritant Anolyte is welcome where traditional chemicals fail to produce the desired results or can’t be applied at all. - Better alternative
The conclusions prove that Anolyte being a low-cost and powerful disinfectant is set to become the preferred solution for many sterilization, disinfecting and water purification procedures.
Undertaken by Institute of Chemistry of Tallinn Technical University, Estonia.
Daphnia magna 24 hours acute toxicity tests were carried out according to Finnish standard SFS 5062
The dilutions used were:
- Anolyte medium : 1:100, 1:500 and 1:1000
- Anolyte strong: 1:50, 1:200 and 1:500
The acute toxity of Anolyte
Anolyte type | Dilution | EC50; % (confidence limit) | EC50; % for initial anolyte |
Anolyte medium | 1:100 | 25 (22.5-28) | 0.25 |
1:500 | Not toxic | ||
1:1000 | Not toxic | ||
Anolyte strong | 1:50 | 13 (11-16) | 0.26-0.28 |
1:200 | 56 (52-59) | ||
1:500 | Not toxic |
The toxicity test demonstrated that there were no acute effects for the anolyte diluted 1:500 or more. No significant differences in the toxicity of two anolytes (strong and medium) were observed.