Specifications

FIT Specifications

ParameterSpecificationUnit
Rated Output (Max.)125 & 300kW
Rotor Speed0 to 30,000rpm
Volumetric Flow Rate*2,000 to 50,000Nm3/hr**
Gas Temperature-76 to +250deg F
Housing MAWP1,600psi-g
Housing CertificationIECEx Hermetic Explosion Proof
Environmental Temperature-40 to +140deg F
Length (Flange-to-Flange)47in
Diameter23in
Weight2,400lb
* Acceptable flow rate depends on the inlet temperature and inlet pressure
* Normalized conditions are 32 deg F & 14.5 psi

VSD Specifications

ParameterSpecificationUnit
Output Current190 (for 125kW) & 460 (for 300kW)Amps RMS
Output Voltage380 to 480VAC
Output Freq.50 to 60Hz
System Output3-Phase, 3-Wire
Grid Harmonics< 5% THD per IEEE 519
Serial InterfaceModbus RTU over RS-485
Enclosure Cert.NEMA-4X
Environmental Temperature+32 to +140deg F
Dimensions (H. x W. x D.)84 x 54 x 39in
Cooling RequirementsLiquid-cooling, 50 LPM @ 104 deg F & 29 psi max.
System operation and power generation depends on gas composition and application specific requirements